Model |
Ihold(mA) |
Itrip(mA) |
Vmax interrupt(V) |
Imax(A) |
Pd max(W) |
Maximum Time to Trip |
Resistance(Ω) |
Current(A) |
Time(S) |
Rmin- Rmax |
JK250-020U |
20 |
45 |
250 |
3 |
1.0 |
0.5 |
0.8 |
50-160 |
JK250-030U |
30 |
65 |
250 |
3 |
1.0 |
0.5 |
1.0 |
40-120 |
JK250-040U |
40 |
80 |
250 |
3 |
1.0 |
0.5 |
1.5 |
30-60 |
JK250-050U |
50 |
100 |
250 |
3 |
1.0 |
0.5 |
2 |
25-50 |
JK250-060U |
60 |
120 |
250 |
3 |
1.0 |
0.5 |
2 |
20-60 |
JK250-080U |
80 |
160 |
250 |
3 |
1.0 |
1 |
0.5 |
12-22 |
JK250-090U |
90 |
180 |
250 |
3 |
1.0 |
1 |
0.8 |
10-20 |
JK250-100U |
100 |
200 |
250 |
3 |
1.0 |
1 |
1 |
10-20 |
JK250-110U |
110 |
220 |
250 |
3 |
1.0 |
1 |
2.0 |
6-12 |
JK250-120U |
120 |
240 |
250 |
3 |
1.0 |
1 |
2.0 |
6-12 |
JK250-145U |
145 |
290 |
250 |
3 |
1.0 |
1 |
5.0 |
3.5-6.5 |
JK250-180T |
180 |
650 |
250 |
3 |
1.8 |
3 |
3.0 |
1.0-2.2 |
JK250-180U |
180 |
650 |
250 |
3 |
1.8 |
3 |
1.5 |
2.0-4.0 |
JK250-200U |
200 |
400 |
250 |
5 |
2.4 |
3 |
5 |
3-6 |
JK250-400U |
400 |
800 |
250 |
5 |
2.8 |
3 |
8 |
1-3 |
JK250-600U |
600 |
1200 |
250 |
5 |
3.2 |
3 |
12 |
0.6-2.0 |
JK250-800U |
800 |
1600 |
250 |
5 |
3.6 |
4 |
18 |
0.4-1.0 |
JK250-1000U |
1000 |
2000 |
250 |
7 |
3.6 |
5 |
20 |
0.3-0.8 |
JK250-1200U |
1200 |
2400 |
250 |
7 |
3.6 |
6 |
20 |
0.2-0.8 |
JK250-1500U |
1500 |
3000 |
250 |
7 |
4.8 |
7.5 |
20 |
0.2-0.6 |
JK250-2000U |
2000 |
4000 |
250 |
10 |
4.8 |
10 |
20 |
0.2-0.4 |
保持电流(I H):25℃静止空气环境中不触发PPTC自复保险丝突越的最高电流。
触发电流(I T):25℃静止空气环境中PPTC自复保险丝从低阻抗转为高阻抗的最小电流。
最大电压(V max):PPTC自复保险丝能承受的最大工作电压。
最大电流(I max):P35倍PTC自复保险丝能承受的最大电流。
动作时间(T trip):指定电流下的最大动作时间。
动作功率(Pd typ):25℃环境温度时PPTC自复保险丝动作状态下的消耗功率。
最小电阻(R min):25℃ 温度条件下最小零功率电阻。
最大电阻(R max):25℃ 温度条件下最大零功率电阻。 |